{"product_id":"goodman-hktsd20db-20kw-240v-electric-heat-kit","title":"Goodman HKTSD20DB 20kW 240V Electric Heat Kit with Circuit Breaker for R-32 Air Handlers","description":"\u003ch1\u003e\u003cspan\u003eGoodman HKTSD20DB – 20 kW 240V Electric Heat Kit with Circuit Breaker\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGoodman HKTSD20DB 20 kW Electric Heat Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides dependable auxiliary, supplemental, and emergency heating for compatible Goodman air handlers and heat pump systems. Designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e240V single-phase applications and approved D-width air handler cabinets\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this electric resistance heat kit features factory-installed circuit breakers, nickel-chromium heating elements, and a dual-circuit electrical configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith a nominal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20 kW heating capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and an actual rated output of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e19.2 kW (approximately 65,513 BTU\/h) at 240V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the HKTSD20DB delivers substantial supplemental heating capacity for properly sized residential and light commercial HVAC applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e20 kW Nominal Heating Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Delivers 19.2 kW or approximately 65,513 BTU\/h at 240V.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e240V Single-Phase Application:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for approved Goodman air handler installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFactory-Installed Circuit Breakers:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides integrated overcurrent protection for the heater circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDual-Circuit Configuration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Features two electrical heating circuits for manufacturer-approved installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary \u0026amp; Emergency Heating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports supplemental and backup heating in compatible heat pump systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNickel-Chromium Heating Elements:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rust-resistant electric resistance elements designed for dependable performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSequenced Heating Controls:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports controlled activation of the heating elements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePlug-In Wiring Harness:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps simplify installation with approved Goodman indoor equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHigh-Temperature Safety Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes protective thermal limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eD-Cabinet Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for qualifying Goodman 24.5-inch nominal D-width air handlers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFactory-Assembled \u0026amp; Tested:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered for reliable installation and service.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHigh-Capacity Auxiliary \u0026amp; Emergency Heating\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Goodman HKTSD20DB provides electric resistance heating when installed in an approved air handler.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIn heat pump systems, auxiliary heat can supplement the outdoor equipment during periods of increased heating demand. When properly configured, the kit can also provide emergency backup heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe electric heating elements generate heat directly, while the air handler blower distributes warm air throughout the conditioned space.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDual-Circuit Design with Circuit Breakers\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe HKTSD20DB features two electric heating circuits equipped with factory-installed circuit breakers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration supports higher-capacity electric heating applications and allows the manufacturer-specified electrical connections and staging arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe kit includes a plug-in wiring harness and high-temperature protective controls to support professional installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatible Goodman D-Cabinet Air Handlers\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Goodman HKTSD20DB is designed for qualifying Goodman air handlers with D-width cabinets, including approved AMST, AMVT, and AHVE equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility depends on the exact air handler model, equipment revision, electrical requirements, and manufacturer-approved heat kit application tables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHKTSD20DB vs. HKTSD20DA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHKTSD20DB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e240V single-phase applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHKTSD20DA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V single-phase applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBoth are nominal 20 kW electric heat kits with factory-installed circuit breakers. The correct model should be selected based on the electrical supply and manufacturer-approved equipment combination.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Installation Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eElectric heat kit with circuit breakers only.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The air handler, outdoor condenser, thermostat, and additional HVAC accessories are sold separately unless otherwise specified.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis kit requires compatible indoor equipment and proper electrical protection. Minimum circuit ampacity, maximum overcurrent protection, and heating airflow requirements must be determined for the complete system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation must be performed by a qualified HVAC professional following Goodman installation instructions and applicable electrical and mechanical codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOrder the Goodman HKTSD20DB 20 kW Electric Heat Kit with Circuit Breaker from EZ Plenum\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for your next compatible HVAC installation, heating upgrade, or replacement project.\u003c\/span\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":67775828263012,"sku":"HKTSD20DB","price":319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/8852\/8228\/files\/goodman-hktsd20da-db.png?v=1792336529","url":"https:\/\/ezplenum.com\/products\/goodman-hktsd20db-20kw-240v-electric-heat-kit","provider":"EZ Plenum","version":"1.0","type":"link"}